Home | Survey | Payment| Talks & Presentations | Job Opportunities
Journals   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
High Voltage Engineering
1003-6520
2013 Issue 3
Simulated Analysis of Lightning Shielding Failure Performance of UHVAC Transmission Lines
YAO Chenguo;WANG Tingting;YANG Qing;SIMA Wenxia
..............page:526-533
Voltage Response of Trapped Charge Release of No-load Bus in Gas Insulated Substation
LU Binxian;ZHAO Nan;ZHENG Xiayang
..............page:534-540
Segmented DC Ice-melting Solution of UHV DC Transmission Lines
LU Jiazheng;TAN Yanjun;LI Bo;FANG Zhen;ZHANG Hongxian
..............page:541-545
Natural Contamination Deposited Characteristics of ±800 kV UHV DC Insulators at High Altitudes
L(U) Fangcheng;QIN Chunxu;GUO Wenyi;LIU Yunpeng
..............page:513-519
Non-fault Identification Voltage and Current Based Integrated Criterion for Single-phase Reclosure on UHVAC Transmission Lines
SHAO Wenquan;ZHANG Xiaowei;SONG Jiangxi;NAN Shugong;LI Yanbin
..............page:546-554
Overvoltage Mitigation and Insulation Coordination of ±1000 kV and Above DC Transmission Project
ZHANG Cuixia;CHEN Xiujuan;GE Dong;JIAO Fei;ZHANG Liuchun
..............page:520-525
Operation Losses and Economic Evaluation of UHVAC and HVDC Transmission Systems
LIANG Hanqing;WU Xiong;LIANG Xuming
..............page:630-635
Influence of Fog Water Conductivity on AC Corona Characteristics of Transmission Line
JIANG Xingliang;HUANG Jun;DONG Bingbing;ZHOU Longwu;YUAN Chao
..............page:636-641
Influence of UHVDC Transmission System Dynamic Response on AC Receiving End's Failure Recovery Characteristics
ZHENG Chao;SHENG Canhui;LIN Junjie;XUE Jingying;CHEN Dezhi;ZHANG Zhiqiang
..............page:555-561
Calculation of Effective Permeability of Flake Particles with Various Arrays
XU Xiaoying;CHEN Yangfan
..............page:642-647
Transient Rating Calculation of AC Filters in ±800 kV UHV DC Transmission Project
LI Jingyan;YANG Yiming;WU Fangjie
..............page:562-567
Approximate Characteristics of Lightning Electromagnetic Field in Nearby Area Generated by Oblique Channel
WANG Xiaojia;CHEN Yazhou;LI Bing;WAN Haojiang;WANG Lin
..............page:648-654
Characteristics of Potential Transfer Current of ±-800 kV UHVDC Transmission Line
LIU Kai;WU Tian;LIU Ting;XIAO Bin
..............page:568-576
Analysis on Potential Rise on UHV Oil-paper Capacitor Bushing's End Shield Under Lightning Impulse Test
HU Wei;XU Zuoming;ZHANG Shiling;XIE Xiongjie;HUANG Hua;PENG Zongren
..............page:577-583
Corona Characteristics of Insulator String Grading Ring for 500 kV Substation at Ultra High Altitude
WANG Hongying;XIA Jingxin;HUANG Daochun;RUAN Jiangjun;CHEN Yong
..............page:661-667
Lightning Performance Simulation of Quadruple-circuit Transmission Line with Dual Voltage 1000 kV/500 kV on the Same Tower
FAN Mian;WAN Lei;DAI Min;HE Huiwen;LI Zhijun;GU Dingxie
..............page:584-591
Fast Computation Method for Numerical Model in FDTD of Reverberation Chamber
WANG Song;WU Zhancheng;CUI Yaozhong;DU Lei;CHENG Erwei
..............page:682-688
Simulation and Experimental Analysis of Corona Loss of 1000 kV and 500 kV AC Transmission Lines on Same Tower
XIE Xiongjie;LIU Qin;HUO Feng;ZHU Lei;LIU Yunpeng;ZHOU Guoyang
..............page:592-596
Modeling for De-icing Automatic Defense System of Transmission Lines and Analysis of Influence on Power Grid
LI Xiaoming;ZHOU Dongxu;JIANG Jianfei;MA Fahao;XU Jie;LI Jun
..............page:698-704
Analysis of Simulative Calculation and Measurement of Radio Interference from Yunnan—Guangdong ±800 kV UHVDC Transmission Lines
DENG Jun;XIAO Yao;CHU Jinwei;LI Licheng;ZHAO Yuming;ZHANG Jiangong
..............page:597-604
Analysis on Circuit Breaker Transient Recovery Voltage UHV AC Transmission Lines Fixed with Series Capacitors
ZHENG Bin;XIANG Zutao;BAN Liangeng;GU Nihong;WANG Xiaotong;HAN Bin
..............page:605-611
Design and Application of DC Deicer for AC Transmission System
FU Chuang;XU Shukai;RAO Hong;LI Xiaolin;CHEN Yiping;LI Licheng
..............page:705-711
Study on Flashover Model of UHV Substation Post Insulator in Serious Icing Condition
LI Xuelin;YAO Tao;LI Jin;CAI Lin;JIA Ru
..............page:612-617
Analysis of Key Technical Parameters of Arresters Used for 1000 kV UHVAC Transmission Line with Series Gap
ZHANG Boyu;SU Ning;L(U) Xuebin;ZHANG Cuixia;YIN Yu;CHEN Lidong
..............page:618-622
Mode Analysis of a Resonant Pole Soft-switching Inverter
HE Hucheng
..............page:719-726
Analysis and Numerical Calculation on Breakdown Time of Three-electrode Trigatron Gap
CAI Li;CAI Yun;LIN Fuchang;LI Li;QI Xiangdong;BAO Chaobin
..............page:727-732
Temperature Calculation and Property Analysis of Metal Oxide Varistor Based on Coupled Fields
TANG Zonghua;TAN Zhenyu;SUN Shumin;LI Guanglei
..............page:733-740
Equivalent Circuit and Its Applications for Multilevel Matrix Converter
LI Lijuan;WANG Feng;YI Lingzhi;DENG Wenlang;ZHU Jianlin
..............page:741-748
Insulated Tower Head of 10 kV Overhead Distribution Line Used for Lightning Protection
BIAN Kai;CHEN Weijiang;SHEN Haibin;LI Chengrong;YIN Bin;CHEN Kang
..............page:749-754
Impact Analysis of Transmission Line Span Combination on Dynamic Characteristics of Iced Conductor
ZHANG Huan;LI Wei;ZHANG Yajun;WANG Liming;SUN Baoqiang;FU Guanjun
..............page:755-761