Home | Survey | Payment| Talks & Presentations | Job Opportunities
Journals   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Insulators and Surge Arresters
1003-8337
2015 Issue 3
Study of Insulator Surface Discharge Quantitative Evaluation Method Based on Ultraviolet Imaging Relative Spot Area
DING Pei;MA Feiyue;GAO Yuan;HAO Jinpeng;LI Junhao;LI Yanming;Electric Power Research Institute of State Grid Ningxia Electric Power Company;School of Electrical Engineering;Xi’an Jiaotong University;
..............page:1-4+12
Influence of Polluted Insulator Salt Migration on the Icing Condition and the Leakage Current
MIAO Fengyu;ZHANG Yingmin;CHU Zhengchao;WU Haozhe;Electrical Information College;Sichuan University;China Electric Power Research Institute;
..............page:5-12
Research of Insulated Tension Rod with Highier Voltage Levels
WANG Rui;HOU Mei;XIE Ruiguang;ZHANG Zhuo;CHEN Xin;Shannxi Institute of Electronics;Xi’an Chaoma Composites company;School of Materials Science and Engineering;Xi’an Jiaotong University;State Grid Smart Grid Research Institute;
..............page:13-15+22
Study of the Fault Mechanism and Preventive Countermeasures of BirdTrouble to High Voltage Transmission Lines in Henan Province
LI Changkan;LU Ming;PANG Kai;DENG Peiyuan;Natural History Museum of Zhengzhou Normal University;Zhengzhou Biological Species Resource Research Key Laboratory;State Grid Henan Electric Power Company;HAEPC Electric Power Research Institute;
..............page:16-22
Analysis on the Causes of the Core Rod Fracture of 500 kV AC Composite Insulator
LU Ming;HU We;LI Li;LI Yaoqin;WANG Can;MA Deying;State Grid Henan Electric Power Research Institute;State Key Laboratory of Advanced Electromagnetic Engineering and Technology;
..............page:23-28+34
The Impact of Zero and Low Resistance Insulator on Potential and Electric Field Distribution of Long Insulator Strings in the 500 kV Transmission Line
CHEN Yao;ZOU Dehua;NIU Jie;LUO Richeng;TANG Xiangsheng;School of Electrical and Information Engineering;Changsha University of Science and Technology;Live Operations Center in Hunan;
..............page:29-34
Development and Application of General Tools for Live Replacing Insulator String of L Type on 500 kV Transmission Lines
XIAO Xiangqi;ZOU Dehua;ZENG Xiangjun;LIU Tuosheng;GUO Hao;Hunan Province Key Laboratory of Smart Grids Operation and Control;State Grid Hunan Electric Power Company;
..............page:35-42
Study on Surface Dynamic Contact Angle of Silicone Rubber Materials Used for Composite Insulator
JING Qian;PENG Jing;LIU Yuxin;ZHANG Changzheng;Xi′an High Voltage Apparatus Research Institute Co.;Ltd.;
..............page:43-47
Research on Matching Performance between Multi-Electrodes Gas Discharge Tube and Zinc Oxide Varistors
LI Xiangchao;CHEN Puyang;XU Le;WANG Chengfang;YE Ting;Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration;Nanjing University of Information Science and Technology;
..............page:48-56
Analysis and Experiment Research on the Protection Distance of Arrester with Protected Circuit Breaker in Hot Standby State
QIU Huimin;School of Electrical Engineering;Wuhan University;
..............page:57-61
Study on the Thermal Characteristic of Polymeric Housed MOA without gap
SANG Jianping;WU Liang;LIU Yunwei;YU Longlong;Xi’an High Voltage Apparatus Research Institute Co.;Ltd.;
..............page:62-68+73
MOA Failure Diagnosis and Practical Case Analysis Based on Live Detection Technology
WANG Xiaobo;State Grid Xiaoshan Electric Power Bureau;
..............page:69-73
Determination Method for Gap Distance of Line Surge Arrester with Series Gap based on Normal Distribution
ZHANG Xuejun;SHENG Junhao;GAO Weiqing;LIU Neng;YANG Xin;Zhejiang Xinchang Electric Power Supply Company;Hunan Province Higher Education Key Laboratory of Power System Safety Operation and Control;
..............page:74-78+83
Investigation on the Lightning Withstand Level of Catenary Considering Power Frequency Voltage
YANG Yuxin;ZHANG Youpeng;School of Automation & Electrical Engineering;Lanzhou Jiaotong University;
..............page:79-83
Shielding Failure Trip-out Rate Calculation and Lightning Protection Strategy Making Based on More-refined Topography Influence Factor
WU Min;ZHAN Chun;GU Shanqiang;LIN Qing;ZHOU Hang;WANG Tao;Wuhan NARI Limited Liability Company of State Grid Electric Power Research;
..............page:84-88+95
Study for On-Line Monitoring of Arrester in Traction Supply System
YAO Xiaotong;WANG Jirong;Lanzhou Jiaotong University;
..............page:89-95
Study of Lightning Performance of Substation Connecting to Higher Voltage Transmission Line
WAN Lei;FAN Mian;WANG Lei;China Electric Power Research Institute;
..............page:96-102
Fault Indicator and Disconnector of CT Type Arresters
MAO Huiming;XU Xianming;XI’an Xirun Electric Apparatus Technology Co. Ltd;Jiangsu Xinao Power Technology Co.;Ltd.;
..............page:103-104+109
Simulation Study of Line Arrester under Lightning Shielding Failure
GE Luo;WEN Xishan;School of Electrical Engineering Wuhan University;
..............page:105-109
Study on the Potential Distribution Testing Method for Arresters
WU Liang;Xi’an High Voltage Apparatus Research Institute Co.;Ltd.;
..............page:110-114
Analysis on the Test about 1mA DC Voltage Value of 35 kV MOA
ZHANG Yu;ZHU Zehui;ZHANG Chunhui;YANG Yunyang;XIA Bin;College of Electrical & Information Engineering;Changsha University of Science and Technology;Changsha Xinchang Electric Technology Company;
..............page:115-119
Research on EMI Filter to Suppress VFTO Conducted Interference on Smart Components
LIU Mingyang;HE Tengfang;CAO Zhiping;SHI Kai;ZHOU Lixing;School of Electrical and Information Engineering;Changsha University of Science & Technology;
..............page:120-125
Experimental and Simulation Analysis on Ground Potential Breakdown Characteristics of the Lightning Distribution Grounding System
ZHU Zewei;GUO Zaihua;FAN Juan;ZHANG Fan;WU Guangning;Chengdu University of Information Technology;Jinhua Meteorological Office of Zhejiang Province;Southwest Jiatong University;
..............page:126-131
Analysis and Application on Partial Discharge Map of the Arrester Based on Wide-Band Pulse Current Method
CHEN Xianxi;WANG Junbo;TAN Xiao;LIU Hao;TANG Qi;XING Likun;Guangdong Power Grid Corporation Foshan Power Supply Bureau;Foshan University;
..............page:132-137
Study on the Lightning Back Flashover Performance of Multi-circuit Transmission Lines with Different Operating Voltages
GU Yue;ZHANG Yuan;LI Jiangtao;PENG Ye;CHEN Wenzhong;YU Jiang;School of Electrical Engineering;Xi’an Jiaotong University;China Southern Power Grid Control Center;
..............page:138-142