Home | Survey | Payment| Talks & Presentations | Job Opportunities
Journals   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Insulators and Surge Arresters
1003-8337
2014 Issue 5
Effect of Haze Weather on Leakage Current of Insulators
ZHANG Pengfei;DENG Wei;ZHU Hongzhao;ZHENG Zhongsheng;LI Bing;GAO Xu;KE Rui;Hefei Power Supply Company;State Grid Electric Power Research Institute;
..............page:1-5
Coupling Dimensions Research for Extra Strength Classes of Line Insulator
DING Jingling;DANG Zhenping;Xi’ an High Voltage Apparatus Research Institute Co.;Ltd.;
..............page:6-10+16
Study on Electric Field Distribution of Composite Insulator under Different Hydrophobicity Levels
DU Sisi;ZHANG Xuefeng;YANG Jun;Wuhan NARI Co.;Ltd.;State Grid Electric Power Research Institute;Graduate School of Jiangxi University of Science and Technology;
..............page:11-16
Influence of Optical Electric Field Sensor Performance on Faulty Insulator Detection Results
YANG Tiejun;XU Jinjiang;Electric Power Research Institute of Liaoning;Kangpu Changqing Software Technology Ltd.;
..............page:17-20
Study on the Fiber Bragg Grating Online Monitor Technology Applied in Icing State Monitoring of Transmission Lines
WANG Lei;CAO Min;LIANG Shibin;QIN Zhaoyu;KE Lei;Wuhan NARI Co.;Ltd.;State Grid Electric Power Research Institute;Yunnan Electric Power Test & Research Institute Electric Power Research Institute Company Limited;
..............page:21-24
Experimental Study of RTV Coating in Anti-Icing of Transmission Lines
ZHU Changcheng;LAN Lei;Hubei Electric Power Test and Research Institute;Wuhan University;
..............page:25-30
Study on Electric Field Distribution of Composite Insulator Under Pollution Conditions
LIU Xiangshi;HAEPC Zhumadian Power Supply Company;
..............page:31-36
Simulation Study of the Magnetic Field Inside the Building Caused by Direct Lightning Stroke
SU Zhiguo;ZHANG Yunfeng;WANG Wanfu;WANG Rongzhu;Key Laboratory for Aerosol-Cloud-Precipition of China Meteorological Administration;Nanjing University of Inform ation Science and Technology;Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters;Nanjing University of Information Science & Technology;Shanghai Key Laboratory of Electromagnetic Environmental Effects for Aerospace Vehicle;
..............page:37-40+45
Electric Field Analysis and Optimized Design of the Arrester on 500 kV Transmission Lines
ZHANG Aiwu;LIU Chunxiang;ZHU Hongzhao;GAO Xu;State Grid Electric Power Research Institute;
..............page:41-45
Influence of Different Current Based on Transient Thermal Impedance Model on Heat Dissipation Potential of the Metal Oxide Varistor
ZHANG Xin;YANG Tianqi;YANG Zhongjiang;Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration;Nanjing University of Information Science & Technology;Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters;Nanjing University of Information Science & Technology;Nanjing Service Center of Meteorology;Nanjing Meteorological Bureau;College of Atmospheric physics;Nanjing University of Information Science & Technology;
..............page:46-48+54
TVS Diode Power Analysis in BNC Type Signal Surge Protector Device
YE Ting;YANG Zhongjiang;ZHU Sainan;WANG Chengfang;Key Laboratory for Aerosol-Cloud-Precipition of China Meteorological Administration;Nanjing University of Information Science & Technology;School of Electronic & Information Engineering;Nanjing University of Information Science and Technology;
..............page:49-54
Discussion of Diagnosis Technology of On-Site Live Testing of MOA
LUO Zanchen;Nanning Electric Power Bureau;CSG EHV Power Transmission Company;
..............page:55-59+65
Risk Assessment Method of Lightning Disaster about Ordinary Buildings Based on the BP Neural Network Process
HUA Chenhui;YANG Zhongjiang;LUO Suxuan;LU Ming;Nanjing University of Information Science& Technology;Shaoxing Meteorological Bureau;Lightning Protection Center of Tibet Autonomous Region;Deqing County Meteorological Bureau;
..............page:60-65
Analysis of MOV Simulation Model Based on ATP-EMTP
WANG Rongzhu;ZHANG Yunfeng;CHEN Zehuang;SU Zhiguo;Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration;Nanjing University of Information Science & Technology;State Key Laboratory of Meteorological Disaster of Ministry of Education;Nanjing University of Information Science & Technology;
..............page:66-70
Influence of Topography to Maximum Shielding Current of 330 kV Double-Circuit Transmission Line
MA Huan;GUO Jie;MA Ye;JIAO Lixin;LONG Rui;College of Electrical Engineering;Xi’an Jiaotong University;
..............page:71-75
Analysis on the Tripping Accident of Transformer Owing to Arrester Single-Phase Ground
GUO Lei;WANG Wei;FAN Dongfang;DONG Lijie;HAEPC Electric Power Research Institute;
..............page:76-79+86
Analysis on the Application of Triggering and Arc Extinction Technologies on Several Switching Type SPDs
WANG Shicheng;DU Zhihang;CAO Xinxing;LI Xiangchao;Jiangsu Taizhou Meteorological Bureau;Nanjing University of Information Science & Technology;Shanghai Electric Power Design Institute;Civil Aviation Bureau Sanya Safety Supervision and Management Bureau;
..............page:80-86
Coordination Tests between SPDs and between SPD and Equipment
ZHAO Yang;XING Hongyan;LIU Feifan;Nanjing University of Information Science & Technology;Shanghai Lightning Protection Center;Shanghai University of Electric Power;
..............page:87-93
Research on the Lightning Disaster and Lightning Warning Measures of Building Integrated Photovoltaic
YANG Lei;TAN Yongbo;QIANG Yuhua;School of Atmospheric Physics;Nanjing University of Information Science & Technology;Lishui Meteorological Bureau;
..............page:94-99
Analysis on Impact of Lightning Urban Rail Tower on the Rectifier Substations
ZHANG Dong;TAO Fengyuan;DONG Xinsheng;Xinjiang Electric Power Research Institute;Electric Power Bureau of Luohe;
..............page:100-104
Calculation of Induced Overvoltage on Transmission Line Based on Wagner Field Cancellation Method
ZHANG Xun;ZENG Huarong;LI Yanling;LIU Hualin;ZHOU HAI;HUANG Junkai;Guizhou Electric Power Testing and Research Institute;School of Electric Engineering;Guizhou University;
..............page:105-108+115
Development of Television Networks Signal Surge Protection Device Based on Band-Pass Filter
LI Xiangchao;WANG Chengfang;ZHOU Zhongshan;CHEN Puyang;XU LE;Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration;Nanjing University of Information Science and Technology;
..............page:109-115
Analysis on Capacitance Variation During Impulse Current Conditioning of Zn O Varistor
CHEN Puyang;YANG Zhongjiang;LI Xiangchao;YE Ting;ZHOU Zhongshan;Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration;Nanjing University of Information Science and Technology;School of Atmospheric Physics;Nanjing University of Information Science and Technology;
..............page:116-121+127
Application of the Polar Localization Method in 10 k V Arrester Fault Location
QIU Taihong;WANG Junbo;LI Guowei;HE Shenghong;DONG Di;HU Cong;Foshan Power Supply Bureau;Guangdong Electric Power Grid Corporation;
..............page:122-127
Analysis of Glowing and Arcing Discharge Performance of Switching Surge Protector
ZHOU Zhongshan;ZHANG Yunfeng;WANG Chengfang;CHEN Rongjian;Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration;Nanjing University of Information Science and Technology;The School of Atmospheric Physics;Nanjing University of Information Science and Technology;
..............page:128-134