Home | Survey | Payment| Talks & Presentations | Job Opportunities
Journals   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Proceedings of the Chinese Society for Electrical Engineering
0258-8013
2010 Issue 4
Application of Advanced Power Electronics in Smart Grid
ZHANG Wen-liang;TANG Guang-fu;ZHA Kun-peng;HE Zhi-yuan
..............page:1-7
Novel Fault Diagnosis Approach of Smart Transmission Grid Based on Knowledge Grid Technology
ZHOU Zi-guan;BAI Xiao-min;LI Zai-hua;XU Jing;LI Xiao-jun;LI Hui-ling
..............page:8-15
Optimal Model and Its algorithm for Determining the Components Type in HVDC Systems
XIE Kai-gui1;WANG Li-bin1;LIU Ying-shang2;HU Bo1;HUANG Ying3;CAO Kan1;Shapingba District;Chongqing 400044;China;2. China Southern Power Grid Co.;Ltd.;Guangzhou 510623;Guangdong Province;China;3. China Southern Power Grid Technology Research Center;Guangzhou 510623;Guangdong Province;China)
..............page:16-21
A Method for Assessing Customer Harmonic Emission Level Based on the Dominant Fluctuation Filtering Principle
GONG Hua-lin;XIAO Xian-yong;LIU Ya-mei;YANG Hong-geng
..............page:22-27
Harmonic Analysis Based on Kaiser Window Interpolation FFT and Its Application
GAO Yun-peng;TENG Zhao-sheng;WEN He;ZENG Bo
..............page:43-48
Impact of Electromechanical Coupling on Shaft Torsional Dynamics
CHEN Wu-hui1;BI Tian-shu1;YANG Qi-xun1;PENG Qian2;Ministry of Education;Changping District;Beijing 102206;China;2. State Nuclear Electric Power Planning Design and Research Institute;Haidian District;Beijing 100094;China)
..............page:49-55
On-line Voltage Stability Monitoring Applying Local Area Measurements
LIAO Guo-dong;WANG Xiao-ru
..............page:56-62
Small Signal Stability Analysis of the Large-scale Wind Farm With DFIGs
WANG Chen1;SHI Li-bao1;YAO Liang-zhong2;WANG Li-ming1;NI Yi-xin1;Shenzhen 518055;China;2.AREVA T&D Technology Centre;Stafford ST17 4LX;United Kingdom)
..............page:63-70
Modeling of a Large-scale Wind Farm and the Studying for Its Security and Stability Operation in Inner Mongolia Grid
HOU You-hua1;QI Jun2;WANG Xiao-hai2;WAN Jiang2;ZHANG Hong-guang2;YANG Tao2
..............page:71-78
Fast Estimation Method for Steady-state Voltage Stability Margin Based on Node Thevenin Equivalent
LI Lian-wei;WU Zheng-qiu;ZHONG Hao;KUANG Hong-hai;LUO Hua-wei;LI Ri-bo;ZHANG Xiao-bing
..............page:79-83
Risk Assessment of Backbone Communication Network in WAMS
PENG Jing1;LU Ji-ping1;WANG Yang1;LIU Jia-wei2;Shapingba District;Chongqing 400030;China;2. Chongqing Power Company Shapingba Power Supply Bureau;Shapingba District;Chongqing 400030;China)
..............page:84-90
Identification of Permanent Faults for Three-phase Adaptive Reclosure of the Transmission Lines With Shunt Reactors
SHAO Wen-quan;SONG Guo-bing;SUONAN Jia-le;LIANG Zhen-feng
..............page:91-98
Application of Anti-vibration Aid-design Expert System for Long-span Overhead Line
WANG Hong1;LIU Yi-bing1;WANG Jing-chao2;XU Hong1;CAO Dao-zhen2
..............page:99-104
Test Results and Analysis of Altitude-change Effect on Audible Noise of AC Corona Occurring on Conductors With Corona-test Cage
TANG Jian1;HE Jin-liang1;LIU Yun-peng2;YANG Ying-jian2;CHEN Yu-chao2;Haidian District;Beijing 100084;China;2. State Grid Electric Power Research Institute;Wuhan 430074;Hubei Province;China)
..............page:105-111
Study of Charge Accumulation Along the Insulator Surface in the DC GIL
JIA Zhi-jie1;ZHANG Bin1;FAN Jian-bin2;LI Jin-zhong2;LI Peng2;ZHANG Qiao-gen1
..............page:112-117
Effects of Air Pressure and Humidity on the Characteristics of Negative DC Corona
BIAN Xing-ming 1;HUI Jian-feng2;HUANG Hai-kun 3;WANG Li-ming4;GUAN Zhi-cheng4;CHEN Yong5
..............page:118-124
Study on Neutral Acid and Water Dissolved in Oil for Different Types of Oil-paper Insulation Compositions of Transformers in Accelerated Ageing Tests
LIAO Rui-jin1;SANG Fu-min1;LIU Gang2;YANG Li-jun1;Shapingba District;Chongqing 400044;China;2. Sichuan Electric Power Test & Research Institute;Chengdu 610072;Sichuan Province;China)
..............page:125-131
On-site Detection of Pollution Level of Insulators Based on Infrared-thermal-image Processing
LI Zuo-sheng1;LI Wen-li1;YAO Jian-gang2;YANG Ying-jian3
..............page:132-138