Home | Survey | Payment| Talks & Presentations | Job Opportunities
Journals   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
High Voltage Apparatus
1001-1609
2009 Issue 4
Research on Equipotential Bonding of Copper Cable in 500 kV Substation
LI Fei;CUI Wen-jie;HUANG Xin
..............page:52-54
Research on Transient Characteristics of CVT and Corresponding Impacts on Microchip Relay Protection
YAO Jian-guang;ZOU Yi-yun;FENG Wei;WANG Suo-kou
..............page:34-36
Differential Protection of Optical-fiber Line Based on Electronic Current Transformer
WANG Xiao-fang;ZHOU You-qing;LI Fu-liang
..............page:29-33,36
Calculation of Distributed Parameters of Transformer Winding Based on the Model of Multi-conductor Transmission Line
RUAN Ling;ZHAO Chun;RUAN Jiang-jun;DU Zhi-ye;CHEN Liang;GAO Sheng-you
..............page:41-46
Effect of Isolating Switch Operation on Very Fast Transient Over-voltage in Extra-high Voltage GIS
LI Dong-yan;RONG Ming-zhe;ZHANG Meng;WANG Xiao-hua
..............page:55-58,62
Research on Suppression of Power Frequency Electric Field Due to EHV Transmission Lines
LI Yong-ming;HE Jian;XU Lu-wen;YANG Yue;JIA Jin
..............page:47-51
Investigation and Design of Partial Discharge Calibrator
WANG Wan-gang;WU Guang-ning;LEI Dong;HE Chang-hong;ZHANG Xue-yuan
..............page:59-62
Numerical Analysis and Measuring for the Potential Distribution of 800 kV MOA
YUE Ya-li;JIANG Shao-cheng;ZHANG Yuan-bin
..............page:63-66,70
The Development of ZW32A-24/T1250-25 Outdoor High-voltage AC Vacuum Circuit Breaker
QIN Xiao-di;XU Jian-Yuan;LIN Xin;WANG Bo;Lu Lu;WANG Liang
..............page:67-70
Field Debugging of Relocatable Static Var Compensator in Jiangxi Province
FAN Rui-xiang;SUN Min;ZHAO Gang
..............page:155-158
An Improved Approach of Grounding Grid Corrosion Diagnosis by Adding Touchable Nodes
LIU Jian;WANG Jian-xin;WANG Sen;LI Zeng-li;LU Wei
..............page:122-125
Overvoitage and Insulation Coordination of 500 kV Autotransformer Neutral Grounding through Small Reactance
FU Zhong;WANG Liu-fang;WANG Qing-jun;ZHANG Hai-bin;ZHU Sheng-long
..............page:126-128
Analysis of Circuit Breaker Failures Due to Lightning Strike in a 220 kV Substation
MAO Wen-qi;HU Xu;DENG Ji;LI Zhi-yu
..............page:153-154
Impact of Oil-Paper Barrier on Detected UHF Signal of Partial Discharge in Transformer
GAO Hong-wu;LI Jian;CHENG Chang-kui;JIN Zhuo-rui;WANG You-yuan
..............page:118-121
Development Review of High Voltage Electriferous Display and Locking Device
SUN Zhen-quan;GU Hong-wei;LI Yan-ming
..............page:115-117,132
New Dielectric Test Method for Oil/Gas Insulated High Voltage Bushing of Transformer
SHEN Ji-liang;HUANG Fu-yong;ZHOU Wei-hua;TANG Mei-yun
..............page:71-73
Power Control of Electronic AC Load Simulator with Reversible Power Flow
LI Shou-rong;TIAN Ming-xing
..............page:12-15
Evaluations of Several Audible Noise Predicting Formulas for 1000 kV UHV AC Transmission Lines
YU Ji-hui;YANG Yue;HE Jian;YANG Guang;JI Juan
..............page:1-4,15
Experimental Study of Electrohydrodynamic Plasma Actuators with Sealed Lower Electrodes
LIU Yong;XU Guang-ke;LI Qing-quan
..............page:21-23
Study on High-frequency Dielectric Barrier Discharge Reactor Structure
ZHU Tao;LI Jian;JIN Yu-quan;LIANG Wen-jun
..............page:16-20
Analysis and Treatment of High Voltage Reactor\'s Abnormal Hydrocarbon Gases for 500 kV Nanchang Substation
YE Ai-min;WANG Xiao-ming;LU Yong-ping;LIU Xiao-bo
..............page:133-134,136
Analysis of GIS Internal Fault Caused by Earthing Switch Operation
ZHANG Yan-tao;WANG Wei;SU Yu
..............page:135-136
Development and Application of UV Imaging Detection Management System for High Voltage Electrical Equipment
WANG Sheng-hui;LU Fang-cheng;LI He-ming;LI Nan;JI Lan-lan
..............page:146-149
Operation Analysis and Improvement Measure of 500 kV Tank Circuit Breaker
GAO Jun;TONG Wei-dong;HUO Feng-ming;HU Tao;LI Xiao-feng
..............page:150-152
An Algorithm of Phase Difference Measurement Based on Fourier Series with Application in Detection of MOA
WANG You-jia;DUAN Da-peng;JIANG Xiu-chen;ZENG Yi;SHENG Ge-hao
..............page:142-145,149
Analysis of the 500 kV Shunt Reactors Operation Condition in Henan Power Grid
WANG Wei;HAN Jin-hua;LI De-zhi;YANG Xiao-hui;WANG Ji;LI Hai-feng;LIU Bo
..............page:82-85
Progress in the Research of Surface Flashover Switch
PAN Ru-zheng;SUN Guang-sheng;YAN Ping;WANG Jue;ZHANG Dong-dong
..............page:111-114,128
Development of High-voltage Electronic Transducers and Their Application in Power System
ZHANG Jian-chao;LIU Xiao-bo;ZHANG Fei;YAN Lu-ming;GUO Ji-fang;GUO Xiao-yan
..............page:106-110
An On-line Monitoring Scheme of Conductor Temperature in GIS Based on Infrared Temperature Measurement
WU Sheng-bin;ZHENG Yan;CHEN Zhi-bin
..............page:100-102,110
Test Equipment of UHV Transformer\'s AC Withstand Voltage and Partial Discharge Tests
QIU Xin-yan;LI Fu-liang;PENG Chun-yan;ZHOU You-qing;PAN Hua
..............page:94-96,99
An Accurate Digital Measurement Method of Power Factor
FENG Xue
..............page:90-93
Research of 10 kV Feeder Inrush Controller
YAN Hong-kui;LIN Xin;XU Jian-yuan
..............page:86-89,93
EMC Design of High Voltage High Power DC Power Supply for ESP
WANG Yan-an;XIAO Deng-ming;LIU Shuai;LI You-huai;CHEN Gui-wen
..............page:77-81