Temperature Rise Calculation for Winding Terminals with High Current
LI Hua-chun;LIANG Zuo-de;LI Jian-ming;SHAO Lei;Shandong Luneng Mount. Tai Electrical Equipment Co.;Ltd;
..............page:1-4
Application of Aluminum Conductor in Resin Cast Dry-Type Transformer
SUN Gen-hui;Tianjin TBEA Transformer Co.;Ltd.;
..............page:5-8
Design and Characteristics of S13 On-Load Capacity Regulating Transformer
LUO Wei-bin;LIU Chang-jiang;LONG Shi-yi;LAI Mei-yun;LUO Jian-jun;ZHENG Zhong-yu;Qingxin Power Supply Bureau;Guangdong Power Grid Co.;Ltd.;Guangdong Guangte Electric Co.;Ltd.;Qingyuan Power Supply Bureau;Guangdong Power Grid Co.;Ltd.;
..............page:9-12
Radiation Noise Calculation of 220kV Transformer
GONG Yi-xiang;XIE Qing-feng;LI Meng;CAO Mei-gen;PENG Ming-cong;HUANG Song-ling;Changzhou Xidian Transformer Co.;Ltd.;Tsinghua University;
..............page:13-16
Analysis of Temperature Rise and Short Circuit Strength for Two Kinds of Cooling Modes of Converter Transformer
WANG Chang-sheng;GAO Feng;HAN Xue-mei;TBEA Shenyang Transformer Group Co.;Ltd.;
..............page:19-22
Research on Present Situation and Trend of Capacity Regulating Transformer
LIU Bin;YUE Qing;SUN Yi-wei;YE Yan-chen;TANG Ming;YAN Shao-yang;Shaanxi Regional Electric Power Group Co.;Ltd.;Xi’an Jiaotong University;
..............page:23-28
Structure Examination and Assessment of Main Transformer for TNPS Phase Ⅰ
LI Xue-yan;YANG Hai-feng;CHEN ke;Jiangsu Nuclear Power Co.;Ltd.;TBEA Shenyang Transformer Group Co.;Ltd.;
..............page:29-32
dian li bian ya qi ji shu zhao biao wen jian zhong de chang jian wen ti qian xi
li ming ; li gang ; an ning ; li sheng qiang ; yi wen xue ;
..............page:33-34
yi zhong 8 zi xing rao zu de rao zhi fang fa he shi yong mo ju
yao qi guo ; zhang bing ; yang wen gan ;
..............page:35-36
Ananlysis of Action Reason of Pressure Relief Device and Its Optimal Measures and Improvement Idea
YU Li-fan;Hangzhou Huadian Xiasha Thermal Power Co.;Ltd.;
..............page:37-39
dian li bian ya qi she ji yu ji suan (52)
liu chuan yi ; hou shi yong ; xu chang hua ;
..............page:40-42
Research on Distribution Transformer Quality Assessment Method Based on Test Data
XU Zhen-yi;LIU Xiao-li;TU Chao;Electric Power Sciences Institute;State Grid Liaoning Electric Co.;Ltd;
..............page:43-46
Research on Overload Performance of Amorphous Distribution Transformer
MA Zhen-yu;JIN Zu-shan;JIANG Jian;State Grid Zhejiang Electric Power Company;State Grid Zhejiang Electric Power Research Institute;Hangzhou Power Supply Company;
..............page:47-51
Research on Electrical Properties of Natural Ester-Paper Insulation of Power Transformer after Thermal Aging
CAI Sheng-wei;ZHOU Cui-juan;CHEN Jiang-bo;YIN Jing;LI Hui;Key Laboratory of State Grid for High Voltage Electrical Equipment Operation Performance Evaluation;China Electric Power Research Institute;
..............page:52-56
Improvement of Forced-Oil Cooler Control Circuit in Transformer
LIN Cong-yu;LIN Xiang-jian;REN Chang-ning;LIN Sen;State Grid Yantai Power Supply Company;
..............page:57-60
Reason Analysis of Main Insulation Fault in 35kV Transformer
SU Lin;Zigong Power Supply Company;
..............page:61-63
Reason of 220kV Main Transformer Folding Screen Discharge and Corrective Actions
ZHAO Xin-yue;WANG Qing-hao;CHENG Shuo;Shenyang Agricultural University;State Grid Fushun Electric Power Supply Company;
..............page:64-67
yi qi zhu bian chu you gui guan lu que xian jian xiu an li ji fen xi
dong zhuo ; fang yi ping ; liu qiu ping ; yin xu ;
..............page:68-69
xi jie jue ding cheng bai duo qi bian ya qi gu zhang fen xi (4)
gong chen bin ; wang shi ge ;
..............page:70-73